BS 9999:2017 Fire safety in the design, management and use of buildings

18th January 2017

Code of practice BS 9999 has been published by BSI, which sets out recommendations and guidance on the design, management and use of buildings to achieve reasonable standards of fire safety for all people in and around them*.  It also provides guidance on the on-going management of fire safety within a building throughout its entire life cycle, including guidance for designers to ensure that the overall design of a building assists and enhances the management of fire safety.

This British Standard is applicable to the design of new buildings, and to alterations, extensions and changes of use of an existing building. It can be used as a tool for assessing existing buildings, although fundamental change in line with the guidelines might well be limited or not practicable. The recommendations and guidance given in this British Standard are intended to safeguard the lives of building occupants and fire-fighters.

Whilst some of the recommendations and guidance might also assist in the achievement of other fire safety objectives – such as protection of property, the environment, communities and business/service viability – it is noted that additional measures might be necessary which are outside the scope of this British Standard.

It is not applicable to individual dwelling-houses, and might have only limited applicability to certain specialist buildings and areas of buildings (e.g. hospitals and areas of lawful detention).

What’s new?

BS 9999 is being fully revised to align with current practices, new technology and other parts of the fire safety standards series, namely BS 9990 and BS 9991. The new edition of BS 9999 introduces the following changes:

  • inclusion of flowchart showing the sequential steps in the design process, to assist users in the application of the standard
  • revised clause on fire safety management with references to PAS 7
  • inclusion of watermist fire suppression systems
  • expansion of guidance on voice alarms
  • expansion of fire growth rates table to provide more information
  • removal of content now covered by BS 9991
  • general update to take into account new and revised standards published since 2008.

The standard also features revised recommendations for:

  • smoke and heat control
  • fire curtain barrier assemblies
  • mechanical ventilation and air-condition systems
  • shopping complexes
  • building exits
  • ducting.

BS 9999 is aimed at a range of stakeholders, including architects, fire safety engineers, fire risk assessors, building control, installers of fire and smoke alarms, sprinklers and smoke and heat control systems, inspectorate for certification and installation schemes, and those involved in emergency lighting.

For further information or guidance on the Code, please contact our specialist team of fire consultants – we’re happy to help.

*Source: BSI